Difference between flry-a and flry-b

Find out what she does within the group and what her experience is. Maria dorovskikh joined the prysmian group through the 2rd wave of build the future, in 20. Widely popular for their superior quality, the products have been produced from the high quality base materials. Soft annealed electrolytic copper cuetp according to din en 602. The main feature is good wear resistance, high temperature in the high temperature, flame retardant, heat resistance are very good. Flryb flrya iccauto 1 2 i dati e le illustrazioni della presente pubblicazione non sono impegnativi e possono essere variati a seguito di modifiche eo perfezionamenti ritenuti opportuni dal costruttore. Iec 60228 is the international electrotechnical commissions international standard on conductors of insulated cables. Car wire harness responsible for the vehicle between the. Click the icon to display the standard color selection table. For wires with higher cable range the asymmetrical formation flryb is mainly used. Flry vehicle cables as per din 72551 part 6 vehicle cables. Hr in prysmian has quite a big impact on the companys performance acting as a business partner. You have clicked a page that seems to be very popular. Conductor softannealed electrolytic copper cuetp1 according to din en 602, bare or tinned.

In turkey you will be exposed to our products and technologies, manufacturing processes, in an in plant experience. Wire description flryb flrya construction wire core. Flrya are pvc automotive cables with thinwalled isolation which are available in single, two and threecoloured versions with a crosssection from 0. Singleconductor cables designed for low voltage electric installations in vehicles. Conductor construction according to iso 6722 concentric. Indication for order please mention the conductor color and color combination clearly to your order, because a reacceptance of false ordered articles is impossible minimum quantities per crosssection and color combination. Its material is generally divided into pp and pa2 species. Flryb automotive low voltage cable fl with reduced insulation thickness. These markings provide important information about the wiring and insulation, including the wire size and material, the type of insulation, the number of wires contained inside a cable, and any special ratings or characteristics of the wire. Products germany standard singlecore cable flrya application this pvc insulated singlecore cable with symmetrical conductor structure type a and thin wall is used for automobiles, motorcycles electrical equipment in high temperature condition.

Conductor softannealed electrolytic copper cuetp1 acc. Flry products are primary wires that conform to automotive manufacturer and iso 6722 specifications. Av avs avss flryb automobile cable automobile cable we are the key manufacturer and supplier of the premium quality range of av avs avss flryb automobile cable. Auto cables flyy control cables building cables rr. Our flry a and flry b cable is available with a black, blue, orange, red and white outersheath as standard. Our products are used in automotive, and motorcycle applications. Copper wire physical and mechanical test 20181218 we provide full test physical and mechanical report for each cable. These auto cables, control cables and building cables are ideal for use in automotive and marine applications where higher current carrying capacity and mechnical strength are required. Lead free thinwall lowtension cable for automobilesflrya, flryb. Flrybtype cables for automotive installations, flryb0. Yet the key difference lies in the temperature profile. Pvc automotive and electric cable with concentric conductor and thin wall insulation. Alibaba manufacturer directory suppliers, manufacturers. Automotive pvc insulated singlecore cable with symmetrical conductor structure type b and thin wall is used.

Flrya comfort and car body, engine and transmission 20 flryb comfort and car body, engine and transmission 21 flyy comfort and car body 33 flr5y engine and transmission 28 flr6y engine and transmission 26 flr7y engine and transmission 25 flry engine and transmission 23 flr14y engine and transmission 27 flrx engine and transmission 22. Chakira cable is the energy and telecom division of the elloumi group cable branch. An offset of maximum 1 mm between the two ring halves is permissible. Avss thin lowvoltage wires for automobiles thin type2. These cables are produced according to din 72551 and iso 6722 standards. Whats the difference between power cable and control cable. Flrya, flryb, and flryy cables all have good resistance to the cold, having a minimum operating temperature of 40 o c. Nominal crosssection conductor structure resistance at 20c wall insulation thickness outer diameter of number of cable wires single wire diameter max. Flrya, flryb, flryy automobile wire iso6722 standard specification. Any one knows about flrya flryb on 1 7 2018 23 months ago. International leader in the manufacture of electronic, telephone and special cables, operating in tunisia, morocco, portugal and romania. Permissible currents are the currents which the saturation temperatures of conductor up to allowed heat resisted temperatures under the. Electrical wires and cable have markings stamped or printed on their insulation or outer sheathing.

We specialize in producing speaker wire, audio cable, video cable, ul approved wire, as well as automotive wire. Learning about electrical wiring types, sizes, and. Used in motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. Other markings on request the wires can also be supplied with numbers printed on them. Flryb flrya singlecore flexible cable to din 725516. Bellows in the wiring harness in the general accounted for about 60%, or even more. Among other things, it defines a set of standard wire crosssections. Thinner insulation causes that rated voltage of these cables is 60v while for other popular car cables lgys it is 220v and currentcarrying capacity depends on wire crosssection. Custom cable and custom heat shrink shapes are another of our specialties. Since automotive cables fall into the class of lowvoltage wires, no ce marking is needed.

Our core competencies automotive standard cables the automotive standard cables business unit is among the global market leaders for singlecore vehicle cables and supports you through its comprehensive product range with a wide variety of approvals from oems and tier 1 customers. We provide full test physical and mechanical report for each cable. Flrya, flryb, and flryy cables all have good resistance to the cold, having a minimum. As part of the make it training program, you will spend a week in the milan hq for an introduction to the groups strategy, markets and culture, followed by a week spent at our state of the art manufacturing academy based in mudanya, turkey. Wires used in low voltage circuits in such as starting, charging, lighting signal and instrument panel circuits. Flrya 0,5 sn swws leiter verzinnt flrya 0,5 sn bkwh conductor tinned flrya 0,5 swws leiter blank flrya 0,5 bkwh conductor bare bemerkungen. Single wires ul csa single wires flat cables multicore cables multicore ul csa cables. Fr type frls type conductor type aluminium or copper and class of conductor cl. If you sum up the cable ranges of the single strands of a wire you usually will. The data and sketches of this technical leaflet are not binding and can be varied as a.

1515 507 1515 714 364 1388 915 854 1249 1164 445 284 555 339 576 1351 357 427 1152 372 1393 1362 1352 895 1484 806 451 329 980 155 975 195